Ev » Installation And Commissioning Of Paste Filling Machines

Installation And Commissioning Of Paste Filling Machines

Installation and commissioning of pasta doldurma maşınları
1. After the machine is unpacked, install according to the “Installation Schematic Diagram” and connect the compressed air source. The pressure of the gas source is 0.6 MPa. If the compressed air main pipeline is connected, the valve should be installed first.
2. Open the right door and turn on the oil mister oil standard to add clean special oil or sewing machine oil. Note: Do not bring air pressure when refueling. It is advisable to increase the oil volume to 8 minutes. .
3. Pass in the air source to check whether the sealing surfaces are leaking. Adjust the air pressure to 0.3 ~ 0.4 MPa to adjust the amount of oil. After spraying a few drops of oil, you can check the fuel injection regularly.
4.Filling volume adjustment: first rotate the filling volume to adjust the hand wheel, observe the indication window scale to achieve the required filling volume, and adjust the suction and discharge speed to achieve a satisfactory filling effect. Volume and finally correct the filling volume.


Cleaning requirements
Wash thoroughly before operation. Wipe off oil or dirt with a soft non-woven cloth and detergent, then wipe dry with a soft non-woven cloth.
In accordance with GMP requirements, check whether the parts in contact with the equipment meet the corresponding cleanliness requirements. If not, clean and dry again. The cleaning method is based on process requirements.


Operation and maintenance
1. The filling operation of the machine is divided into automatic and manual. When the height of the machine is manual, when the manual is used, you only need to push the tongue with the mouth of the bottle to start the suction. Do not hold the tongue when filling. When using automatic, the bottle must be placed under the discharge port, and the filling switch will be started as soon as the switch is turned on automatically, and the bottle will be replaced in time.
2. When the measurement is found to be unstable during filling, check the feed check valve for possible debris trapping, resulting in a tight seal and affecting the filling volume.
3. Leakage in the lower part of the cylinder body indicates that the piston seal is worn and needs to be replaced.